SINO-GALVO HP10-2000 High-Power Galvanometer

Get Instant Quote

Product Details

The HP10-2000 high-power galvanometer has good running stability and strong anti-interference ability, and can be applied to 2000W fiber continuous lasers.


1.HP10-2000 characteristics

The HP10-2000 high-power galvanometer has good running stability and strong anti-interference ability, and can be applied to 2000W fiber continuous lasers. According to the divergence angle parameters of the laser, it is matched with the corresponding QBH beam expansion collimator component. The parallel spot after beam expansion should be ≤10mm, and the field mirror needs to select a quartz field mirror with an incident spot of 10mm.

■ The differential photoelectric sensor detects the position of the motor rotor, with good linearity, small drift, high resolution and repeatability.

■ The load design of the 10mm lens, high motor assembly accuracy, reasonable structure, small static friction coefficient and zero offset, ensure good dynamic characteristics of the system.

■ The driver has position and speed detection functions, which greatly improves the dynamic response performance and scanning speed of the entire system.

■ The design has overload, overcurrent and reverse connection protection, making the system more reliable.

■ The whole system adopts electromagnetic compatibility optimization design, with high signal-to-noise ratio and strong anti-interference ability.

■ The water-cooling structure is used to effectively control the working temperature of the galvanometer.

 

2.HP10-2000 Operation Guide

  1. Before turning on the machine, make sure that the water circuit is connected correctly and the water circulation is normal before turning on the machine, otherwise the galvanometer may be damaged.
  2. Before turning on the machine, please carefully check whether the line sequence of the external connection line of the galvanometer is correct, otherwise it will affect the normal operation or damage of the galvanometer.
  3. The two motors and the two sockets of the driver board must be connected according to the matching serial number and cannot be interchanged, otherwise self-excitation will occur.
  4. Ensure the accuracy of the laser optical path output, otherwise it will affect the marking accuracy. In severe cases, marking displacement and uneven laser power will occur.
  5. Do not adjust the hardware configuration such as the board potentiometer without authorization, and do not disassemble the scanning galvanometer assembly without authorization.

3.HP10-2000 performance technical indicators

Accuracy and error
Step response time (1% of full stroke)288us
Step response time (10% of full stroke)895us
Tracking error≤164us
Linearity99.90%
Repeat positioning accuracy<8μRad
Gain error<5mRad
Zero offset (batch origin error)<5mRad
Long-term drift (continuous operation for 8 hours)<0.5mRad
Proportional drift<40PPM/℃
Zero drift<15μRad/℃
Laser accessories
******Continuous fiber laser power2000W
Lens reflection wavelength1064~1080nm(High power coating)
Water cooling control
Water temperature25±3℃
******Water pressure<3bar
Flow rate>1L/min
Water pipe specificationsouter diameterφ6mm,inner diameterφ4mm
Power supply and signal
Input voltage±15VDC
Rated current2A
Interface protocolXY2-100
Mechanical scanning angle±11°
Working current, temperature, size
Working temperature0℃~45℃
Storage temperature-10℃~60℃
Laser input aperture10mm
Beam displacement13.5mm
Galvanometer size (length × width × height)125.5×100.5×94.1mm
Galvanometer weightabout3kg