SINO-GALVO HP10-2000 High-Power Galvanometer
Get Instant QuoteProduct Details
The HP10-2000 high-power galvanometer has good running stability and strong anti-interference ability, and can be applied to 2000W fiber continuous lasers.
1.HP10-2000 characteristics
The HP10-2000 high-power galvanometer has good running stability and strong anti-interference ability, and can be applied to 2000W fiber continuous lasers. According to the divergence angle parameters of the laser, it is matched with the corresponding QBH beam expansion collimator component. The parallel spot after beam expansion should be ≤10mm, and the field mirror needs to select a quartz field mirror with an incident spot of 10mm.
■ The differential photoelectric sensor detects the position of the motor rotor, with good linearity, small drift, high resolution and repeatability.
■ The load design of the 10mm lens, high motor assembly accuracy, reasonable structure, small static friction coefficient and zero offset, ensure good dynamic characteristics of the system.
■ The driver has position and speed detection functions, which greatly improves the dynamic response performance and scanning speed of the entire system.
■ The design has overload, overcurrent and reverse connection protection, making the system more reliable.
■ The whole system adopts electromagnetic compatibility optimization design, with high signal-to-noise ratio and strong anti-interference ability.
■ The water-cooling structure is used to effectively control the working temperature of the galvanometer.
2.HP10-2000 Operation Guide
- Before turning on the machine, make sure that the water circuit is connected correctly and the water circulation is normal before turning on the machine, otherwise the galvanometer may be damaged.
- Before turning on the machine, please carefully check whether the line sequence of the external connection line of the galvanometer is correct, otherwise it will affect the normal operation or damage of the galvanometer.
- The two motors and the two sockets of the driver board must be connected according to the matching serial number and cannot be interchanged, otherwise self-excitation will occur.
- Ensure the accuracy of the laser optical path output, otherwise it will affect the marking accuracy. In severe cases, marking displacement and uneven laser power will occur.
- Do not adjust the hardware configuration such as the board potentiometer without authorization, and do not disassemble the scanning galvanometer assembly without authorization.
3.HP10-2000 performance technical indicators
| Accuracy and error | ||
| Step response time (1% of full stroke) | 288us | |
| Step response time (10% of full stroke) | 895us | |
| Tracking error | ≤164us | |
| Linearity | 99.90% | |
| Repeat positioning accuracy | <8μRad | |
| Gain error | <5mRad | |
| Zero offset (batch origin error) | <5mRad | |
| Long-term drift (continuous operation for 8 hours) | <0.5mRad | |
| Proportional drift | <40PPM/℃ | |
| Zero drift | <15μRad/℃ | |
| Laser accessories | ||
| ******Continuous fiber laser power | 2000W | |
| Lens reflection wavelength | 1064~1080nm(High power coating) | |
| Water cooling control | ||
| Water temperature | 25±3℃ | |
| ******Water pressure | <3bar | |
| Flow rate | >1L/min | |
| Water pipe specifications | outer diameterφ6mm,inner diameterφ4mm | |
| Power supply and signal | ||
| Input voltage | ±15VDC | |
| Rated current | 2A | |
| Interface protocol | XY2-100 | |
| Mechanical scanning angle | ±11° | |
| Working current, temperature, size | ||
| Working temperature | 0℃~45℃ | |
| Storage temperature | -10℃~60℃ | |
| Laser input aperture | 10mm | |
| Beam displacement | 13.5mm | |
| Galvanometer size (length × width × height) | 125.5×100.5×94.1mm | |
| Galvanometer weight | about3kg | |